CAS 74267-27-9|N,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide

Introduction:Basic information about CAS 74267-27-9|N,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide, including its chemical name, molecular formula, synonyms, physicochemical properties, and safety information, etc.
Common NameN,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide
CAS Number74267-27-9Molecular Weight460.69
Density1.07g/cm3Boiling Point613.7ºC at 760 mmHg
Molecular FormulaC28H48N2O3Melting Point/
MSDSUSAFlash Point325ºC

Names

Namecalcium ionophore ii
SynonymMore Synonyms

BiologicalActivity

DescriptionN,N,N′,N′-Tetracyclohexyl-3-oxapentanediamide (Calcium ionophore II) is a lipophilic ionophore that can be used in preparing calcium ion-selective electrode[1].
Related CatalogResearch Areas >>OthersSignaling Pathways >>Others >>Others
In VitroCalcium ion-selective electrode can be used to measure the intracellular free calcium[1].
References

[1]. Ma YL, et, al. A study of calcium ion-selective PVC membrane electrode based on neutral carrier N,n,n',n'-tetracyclo-3-oxapentanediamide (correction of oxapetanediamide). J Tongji Med Univ. 1992;12(2):98-102.

Chemical & Physical Properties

Density1.07g/cm3
Boiling Point613.7ºC at 760 mmHg
Molecular FormulaC28H48N2O3
Molecular Weight460.69
Flash Point325ºC
Exact Mass460.36600
PSA49.85000
LogP5.99100
Index of Refraction1.536
InChIKeyURAUKAJXWWFQSU-UHFFFAOYSA-N
SMILESO=C(COCC(=O)N(C1CCCCC1)C1CCCCC1)N(C1CCCCC1)C1CCCCC1

Safety Information

Personal Protective Equipmentdust mask type N95 (US);Eyeshields;Gloves
Hazard CodesXi: Irritant;
Risk Phrases37
Safety Phrases22-24/25
RIDADRNONH for all modes of transport
WGK Germany3

Articles9

More Articles
Indo-1 binding to protein in permeabilized ventricular myocytes alters its spectral and Ca binding properties.

Biophys. J. 63(1) , 89-97, (1992)

We have examined the binding of the fluorescent Ca indicator indo-1 to cellular protein in permeabilized ventricular myocytes and also to soluble and particulate myocyte protein. Using either a filtra...

Ion-selective electrode for measuring low Ca2+ concentrations in the presence of high K+, Na+ and Mg2+ background.

Anal. Chem. 69 , 1061-1069, (1997)

In this work, ion-selective electrodes for calcium ion were investigated. Two ionophores were used in the membranes: ETH 1001 and ETH 129. An internal filling solution buffered for primary ion was use...

Induction of a non-specific permeability transition in mitochondria from Yarrowia lipolytica and Dipodascus (Endomyces) magnusii yeasts.

J. Bioenerg. Biomembr. 41(3) , 239-49, (2009)

In this study we used tightly-coupled mitochondria from Yarrowia lipolytica and Dipodascus (Endomyces) magnusii yeasts, possessing a respiratory chain with the usual three points of energy conservatio...

Synonyms

N,N,N',N',-Tetracyclohexyl-3-oxapentandiamin
N,N,N',N'-TETRACYCLOHEXYL-3-OXAPENTANEDIAMIDE
ETH 129
CAS 3567-25-7|Benzenesulfonic acid,5-chloro-2-[4-chloro-2-[[[(3,4-dichlorophenyl)amino]carbon
CAS 102679-70-9|N-CBZ-GLY-PRO-ARG P-NITRO-ANILIDE ACETATE SALT
Recommended......
TOP