CAS 7784-01-2|silver chromate

Introduction:Basic information about CAS 7784-01-2|silver chromate, including its chemical name, molecular formula, synonyms, physicochemical properties, and safety information, etc.
Common Namesilver chromate
CAS Number7784-01-2Molecular Weight331.73000
Density5,625 g/cm3Boiling Point/
Molecular FormulaAg2CrO4Melting Point/
MSDSChineseUSAFlash Point/
Symbol
GHS03, GHS07, GHS08, GHS09
Signal WordDanger

Names

NameSilver Chromate Min
SynonymMore Synonyms

Chemical & Physical Properties

Density5,625 g/cm3
Molecular FormulaAg2CrO4
Molecular Weight331.73000
Exact Mass329.73000
PSA80.26000
InChIKeyOJKANDGLELGDHV-UHFFFAOYSA-N
SMILESO=[Cr](=O)([O-])[O-].[Ag+].[Ag+]
StabilityStable. but light-sensitive and hygroscopic.

Safety Information

Symbol
GHS03, GHS07, GHS08, GHS09
Signal WordDanger
Hazard StatementsH272-H317-H350i-H410
Precautionary StatementsP201-P220-P273-P280-P308 + P313-P501
Personal Protective Equipmentdust mask type N95 (US);Eyeshields;Faceshields;full-face particle respirator type N100 (US);Gloves;respirator cartridge type N100 (US);type P1 (EN143) respirator filter;type P2 (EN 143) respirator cartridges;type P3 (EN 143) respirator cartridges
Hazard CodesO,T,N
Risk PhrasesR8
Safety PhrasesS17-S45-S53-S61-S60
RIDADR3087
Packaging GroupIII
Hazard Class5.1

Articles7

More Articles
Luis Simarro Lacabra [1851-1921]: from Golgi to Cajal through Simarro, via Ranvier?

J. Hist. Neurosci. 10(1) , 19-26, (2001)

Knowledge of cerebral structure and function in its modern form can be traced to the neurone doctrine based largely on the work of Santiago Ramón y Cajal [1852-1934] and his lifelong exploitation of t...

Stabilization of silver chromate Golgi impregnation in rat central nervous system neurons using photographic developers. II. Electron microscopy.

Stain Technol. 62(1) , 7-21, (1987)

The silver chromate precipitate present in neurons impregnated according to the Golgi-rapid and Golgi-Kopsch procedures can be stabilized by treatment with a photographic developer. In a complementary...

Stabilization of silver chromate Golgi impregnation in rat central nervous system neurons using photographic developers. I. Light microscopy.

Stain Technol. 61(6) , 337-52, (1986)

Deterioration of Golgi impregnation begins immediately after impregnated tissue blocks are sectioned with the Vibratome. The first signs of deterioration are fading of delicate impregnated processes, ...

Synonyms

disilver,dioxido(dioxo)chromium
EINECS 232-043-8
MFCD00003402
CAS 860465-97-0|4-iodo-2-(4-isopropylphenyl)-7-methoxy-1-(2-methoxyethyl)-1H-benzo[d]imidazole
CAS 55107-25-0|I+/--(Benzoyloxy)-I+/--2-pyridinyl-2-pyridineacetonitrile
Recommended......
TOP